-40%
FIELD CONTROLS SWG-4HD POWER VENTER, 4" 46275400
$ 201.61
- Description
- Size Guide
Description
Template By Froo!FIELD CONTROLS SWG-4HD POWER VENTER, 4" 46275400
FIELD CONTROLS PART # 46275400
SWG-4HD POWER VENTER
, 4" INLET (HEAVY DUTY) 170,000BTU/HR. 1.10 GPH
For sidewall venting of gas and oil fired equipment
SWG-4D SPECIFICATIONS
PROPERTY OF PATRIOT SUPPLY
MODEL
MAX* OIL GPH INPUT 100psi
MAX* OIL GPH INPUT 140psi
MAX** GAS BTU/hr. INPUT
Maximum Equivalent Feet of Vent Pipe
VENT PIPE SIZE
AT MAX BTU/hr. INPUT
AT 60% OF MAX BTU/hr. INPUT
SWG-4HD
1.1
0.9
170,000
35
100
4"
65
100
5"
PROPERTY
OF
100
100
6"
PATRIOT
SUPPLY
100
100
7"
Gas and oil heating appliances generate heat through the combustion of fuel. The heat is transferred through the heat exchanger and distributed to the conditioned space. The products of combustion, however, must be vented safely out of the structure. In a conventional chimney, venting is achieved by the natural lifting action of the hot combustion gas. New, efficient systems absorb more of the heat in the heat exchanger and produce lower temperature vent gas. Lower temperature gas does not rise as quickly or as reliably as in older, less efficient systems. Power venting or sidewall venting is more economical and safer than chimney venting. A power venter uses a motorized blower to vent the products of combustion. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.
The SWG Power Venter is the safest, most efficient power venter available today.
Patented SWG Power Venters are ETL and cETL listed for all LP gas, natural gas, or oil-fired heating equipment. The SWG combines the motor, blower, and vent hood in one complete, easy to install unit. The SWG mounts on the outside of the building and pulls the combustion gases from the appliance through the outside wall utilizing 100% negative pressure.
Benefits of the SWG Power Venter include:
• 100% negative pressure in the vent pipe for maximum safety.
• Standard galvanized pipe can be used instead of expensive stainless steel.
• No need to seal vent pipe joints, saving time and money.
• Significantly longer vent lengths than positive pressure, direct vent systems.
• The SWG is recommended by major heating appliance manufacturers.
The SWG must be sized to match the appliance or appliances input firing rate. Most firing rates are published in the manufacturer’s installation manual. SWGs must be installed with a CK Control Kit to ensure proper listing and safe, efficient venting.
(CONTROL KITS ARE NOT INCLUDED. MUST BE ORDERED SPEPERATELY)
REPLACES SWG-4, SWG4,